Western Technology VRP100 and
VRP200
VRP 100
The Dynamil Model VRP 100 Precision Spray Etching Machine
can etch up to a 12" X 12" plate using ferric chloride or other compatible
etchants.
Standard equipment includes all PVC construction with CP Titanium
hardware and fittings, titanium 3000 watt heating element, titanium cooling coil, solid
state digital indicating temperature control, full safety interlocks including hood
interlock, low fluid level and over-temperature protection and multi range cycle timer,
baume standpipe, and rinse tank.
- The following factory installed optional equipment will be
required for the Peri-Etch system of copper etching.
-
- .06B Single Pressure Control Valve and Gauge.
-
- .07 & .07B Constant Etch Temperature Control Pump used to
circulate etchant. Also includes hand dispensing hose and nozzle.
-
- .013 Facilities Hook Up Kit includes valves for etchant
drain, rinse drain, cooling coil flow valve, etc.
-
- .024B Chiller System. 220 volt, 1 phase refrigeration
system, uses freon through standard cooling coil. Customer required to charge freon system
and also supply tubing between cooling coil and chiller.
-
- .025 Peri-Etch Sparging System - A series of tubes in Sump,
mixes etchant by circulation of etchant via main pump motor. A separate flow control valve
is provided.
- The following optional equipment is recommended for ease of
operation.
-
- .04A Spray Rinse in rinse chamber replaces standard rinse
overflow system. Dual water spray bars fed by a solenoid regulated water valve uses sprays
to rinse the part instead of a full water tank. Slide gates are provided to be able to
manually rotate work piece disc while sprayers rinse. Actuation can be accomplished by
manual switch actuation or foot operated pedal. Manual Switch supplied if not specified.
-
- .010 Wash-A-Way Hood allows for easy wash down of top of
machine using fresh water inlet. Water drains down through rinse tank.
-
- .015 Digital Scale Timer, blue LED readout with setting
buttons replace analog type motor timer. Required if machine is ordered for 50 hertz
operation.
-
- .016A Exhaust Blower must be ordered in conjunction with
.017B Plenum - Plastic coated blower with single phase motor. Customer must supply 4"
PVC Duct as required to outside of building.
-
- .017B Fume Exhaust Plenum. Top mounted PVC Plenum allows
exhaust to remove fumes from top of machine. Preventing operator exposure.
-
- .027 Polypropelene Catch Tray.
VRP 200
The Dynamil Model VRP 200 Precision Spray Etching Machine
can etch up to a 16" X 16" plate using ferric chloride or other compatible
etchants.
Standard equipment includes all PVC construction with CP Titanium
hardware and fittings, titanium 3000 watt heating element, titanium cooling coil, solid
state digital indicating temperature control, full safety interlocks including hood
interlock, low fluid level and over-temperature protection and multi range cycle timer,
baume standpipe, and rinse tank.
- The following factory installed optional equipment will be
required for the Peri-Etch System of copper etching.
-
- .06A Single Pressure Control Valve and Gauge.
-
- .07 & .07B Constant Etch Temperature Control Pump used
to circulate etchant. Also includes hand dispensing hose and nozzle.
-
- .013 Facilities Hook Up Kit includes valves for etchant
drain, rinse drain, cooling coil
- flow valve, etc.
-
- .024B Chiller System. 220 volt, 1 phase refrigeration
system, uses freon through standard cooling coil. Customer required to charge freon system
and also supply tubing between cooling coil and chiller.
-
- .025 Peri-Etch Sparging System - A series of tubes in Sump,
mixes etchant by circulation of etchant via main pump motor. A separate flow control valve
is provided.
- The following optional equipment is recommended for ease of
operation.
-
- .04A Spray Rinse in rinse chamber replaces standard rinse
overflow system. Dual water spray bars fed by a solenoid regulated water valve uses sprays
to rinse the part instead of a full water tank. Slide gates are provided to be able to
manually rotate work piece disc while sprayers rinse. Actuation can be accomplished by
manual switch actuation or foot operated pedal. Manual Switch supplied if not specified.
-
- .010 Wash-A-Way Hood allows for easy wash down of top of
machine using fresh water inlet. Water drains down through rinse tank.
-
- .011B High Pressure Pump - 1-1/2 HP pump replaces 3/4 HP
standard pump. Not required on VRP 100 Machines, unless used for extra deep etching.
-
- .015 Digital Scale Timer, blue LED readout with setting
buttons replace analog type motor timer. Required if machine is ordered for 50 hertz
operation.
-
- .016A Exhaust Blower must be ordered in conjunction with
.017B Plenum - Plastic coated blower with single phase motor. Customer must supply 4"
PVC Duct as required to outside of building.
-
- .017B Fume Exhaust Plenum. Top mounted PVC Plenum allows
exhaust to remove fumes from top of machine. Preventing operator exposure.
-
- .027A Polypropelene Catch Tray.
[FrontPage Image Map Component]